Powering down high voltage systems is critical for safety

December 13, 2024
Powering down high voltage systems is critical for safety Ensure your multimeter is functional before checking high voltage circuits
Share:

As more EV and Hybrid vehicles come into independent workshops, it has never been more important to follow safe working processes. Before working on any high-voltage system, the Autobiz Helpline knows the importance of powering down high voltage systems, cannot be over-explained.


Sometimes, the removal of the service connector is required, or the removal of a low-voltage interlock plug. Whatever the process, before removing personal protective equipment (PPE), you need to prove the absence of dangerous high voltage.

Voltage levels above 30 volts AC, and 60 Volts DC, are considered hazardous to health. In reality, you are looking for a voltage near zero, in a system that you are going to be working on.

Once you have followed the manufacturer-prescribed process to power down a system, you could use a multi-meter rated to CAT III 1000 volts. But, this can be an issue that you need to consider. Should you trust the accuracy of the test equipment?

When working with high-voltage testing, you should first prove the test equipment is working correctly. Then, test the circuit you are working with. Finally, return to proving your meter is still recording accurately. Only then, can you remove your PPE and begin repairs.

To do this proving process, you should only use an industry-approved proving unit. The recommended process is to use it before testing, and after testing, to confirm the meter is working accurately.

To see or download this article click here.

There are lots more Tech Tips to view, and they are all searchable, on TechTips.ie.

To join the Autobiz Helpline, call 01-905-9500, and then press 2, for further information.

 
Powering down high voltage systems is critical for safety
PREVIOUS ARTICLE
DRI and Serfac focus on sustainability
NEXT ARTICLE
Connect introduces Tesla-Specific Trim Clip Range

More from AFTERMARKET

Motorservice appoints Régis Serrano as new CEO

Motorservice appoints Régis Serrano as new CEO

icon Régis Serrano has been...
SIMI annual awards

SIMI annual awards

icon

The Society of the Irish Mo...

Study finds drivers reluctant to switch to EVs

Study finds drivers reluctant to switch to EVs

icon A new study by consultancy fir...
Sourcing Parts for Japanese Imports

Sourcing Parts for Japanese Imports

icon In our recent article on
Non-cranking Mercedes E220 CDi

Non-cranking Mercedes E220 CDi

icon A 2017 Mercedes E220 CDi was d...
VW Up - Heater Fan Not Working

VW Up - Heater Fan Not Working

icon A Volkswagen Up had an interio...

More from AUTOBIZ